ENGINEERED WATER SYSTEMS

Water Treatment Solutions

Explore how Gravity Water Treatment designs, configures, and deploys high-performance water purification and filtration systems across domestic, commercial, and industrial applications.

Domestic Water Purification for Homes and Apartments

Domestic Water Purification

Tailored drinking water and whole-house protection for apartments, villas, and independent homes.

Safe Drinking Water & Whole-House Plumbing Protection

Drinking water safety in homes requires removing dissolved chemical contaminants, heavy metals, microbial bacteria (such as E. Coli and Coliform), and excessive hardness. Our multi-stage RO+UV+UF purifiers incorporate post-mineralization and copper-zinc technology to deliver balanced, refreshing taste.

For whole-house supply, high iron content in well water causes yellow staining on bathroom tiles and sinks, while hardness causes scale buildup inside geysers and washing machines. Our FRP vessels filter incoming water at the source before it reaches your overhead tank.

Wall-mount & under-sink RO units
Whole-house iron & turbidity removal
Alkaline & copper mineral replenishment
Exchange offers for old purifiers

Continuous Reliability for Hotels, Restaurants & Offices

Commercial establishments cannot afford downtime or inconsistent water taste. In restaurants and cafes, pure water is essential for consistent coffee flavor, beverage preparation, food safety, and spotless glassware.

In offices and commercial buildings, staff and visitors depend on hygienic drinking water. We configure commercial 250 LPH and 500 LPH RO plants paired with stainless steel chilled water coolers to supply hundreds of people daily without plastic bottle waste.

Commercial 250 LPH & 500 LPH RO Skids
Ion-exchange softeners for dishwashers
Food-grade stainless steel piping
Scheduled preventive AMC service
Commercial Water Treatment for Offices, Hotels and Complexes

Commercial Water Treatment

Engineered systems for hotels, bakeries, cafes, offices, auditoriums, and commercial complexes.

Industrial Water Treatment Plants and High-Volume Systems

Industrial Water Treatment

Heavy-duty systems built for production machinery, manufacturing boilers, pharmaceutical cleaning, and food processing.

Heavy Duty Engineering & High Recovery Output

Industrial manufacturing operations demand high water recovery, precise TDS regulation, and continuous 24/7 reliability. Untreated or improperly treated feedwater can cause scale formation in boiler tubes, contaminate chemical formulations, and result in costly downtime.

Our industrial 1,000 to 10,000 LPH RO installations incorporate vertical multistage high-pressure pumps, microprocessor/PLC automation panels, dry-run safety trips, Clean-In-Place (CIP) chemical wash ports, and antiscalant metering to maximize membrane longevity.

PLC automation & rotameter flow monitoring
Electronic antiscalant dosing systems
Robust SS-304 structural skid frames
CIP membrane wash loop piping

EQUIPMENT CATALOGUE

Our Water Treatment Products

Explore equipment for a range of domestic, commercial, and industrial water purification and treatment requirements.

RESIDENTIAL30+ Models
Domestic Purifier - Gravity Water Treatment

Domestic Purifier

Multi-Stage RO + UV + UF, Copper & Alkaline Purifiers

WATER FILTRATIONCustom Vessel
Water Treatment Plant - Gravity Water Treatment

Water Treatment Plant

FRP Vessel Sand, Sediment, Carbon & Iron Remover Filters

COMMERCIAL ROSkid Mounted
RO Treatment Plant - Gravity Water Treatment

RO Treatment Plant

Commercial & Industrial High-Flow RO Plants (50-5000 LPH)

UNDERSTANDING THE PROCESS

RO Water Treatment Plants Explained

Reverse Osmosis (RO) is a pressure-driven membrane separation process. Learn how it works and why customized pre-filtration is essential for success.

1

Pre-Filtration Defense

Raw water passes through multi-grade sand and activated carbon FRP vessels to trap suspended mud, sediment, and chlorine that would otherwise foul and destroy the delicate RO membrane.

2

High Pressure Membrane Separation

A vertical stainless steel booster pump pressurizes water across a semi-permeable Thin Film Composite (TFC) membrane (pores ~0.0001 micron), separating dissolved solids and heavy metals into a concentrate reject stream.

3

Post-Treatment & Disinfection

Permeate water undergoes pH balance, mineralization, and ultraviolet disinfection before being stored in hygienic tanks for consumption or industrial processing.

WHOLE-HOUSE & COMMERCIAL FILTRATION

Iron Removal, Water Softening & Turbidity Solutions

Borewell and open-well water across Kerala commonly contains dissolved iron, heavy turbidity, foul organic odors, and high calcium hardness. Left untreated, iron stains white sanitary fittings and clothing with stubborn yellow/red marks, while hard water causes limescale crust inside geysers and plumbing lines.

Our whole-house filtration plants utilize authentic Pentair and TATA Steel FRP composite pressure vessels packed with catalytic BIRM, manganese greensand, cation softening resin, and high iodine activated carbon. Backwashed effortlessly via top multiport valves to maintain long-lasting purity.

TATA & Pentair FRP Plants

Customized for flow rates from 1,000 to 5,000+ LPH with manual or automated digital multiport valves.

Enquire for Sizing on WhatsApp
ENGINEERING ADVICE

Selecting the Right Equipment

Avoid investing in incorrect filter media or undersized pumps. Consider these 6 key engineering factors before finalizing a system:

1. Source Water Quality

Is your raw water sourced from a borewell, open well, or municipal line? Testing iron (ppm), total dissolved solids (TDS), hardness, and microbiological load dictates the media and membrane selection.

2. Required Water Output & Flow Rate

Domestic homes typically need 15–25 LPH for drinking, or 1,000–2,000 LPH for whole-house usage. Commercial restaurants, schools, and factories require continuous 250 LPH to 1,000+ LPH systems.

3. Daily Consumption Volume

Calculating cumulative daily usage helps determine optimal storage tank capacity and prevents unnecessary pump cycling, extending pump and membrane life.

4. Application & End Use

Drinking water requires strict TDS reduction and sterilization. Boiler feed requires total hardness removal to zero scale. Sanitary and general utility water focuses on iron and sediment removal.

5. Available Installation Space & Plumbing

Assessing indoor vs outdoor footprint, overhead tank elevation, drainage lines for backwash or RO reject water, and single-phase vs three-phase power availability.

6. Maintenance & Operating Regimen

Evaluating whether a manual multiport valve suits the site or if an automatic microprocessor valve with automated backwash cycles is preferred.

Serving Vadakkencherry, Palakkad & Central Kerala

Ready to Transform Your Water Quality?

Schedule a water sample test or discuss your facility requirements with Gravity Water Treatment in Vadakkencherry.

Direct Call: +91 95625 84025
Water Testing Facility Available